News Column

Researchers from Purdue University Detail New Studies and Findings in the Area of Materials Science and Physical Chemistry (QCM-Based Measurement of...

September 5, 2014



Researchers from Purdue University Detail New Studies and Findings in the Area of Materials Science and Physical Chemistry (QCM-Based Measurement of Chlorine-Induced Polymer Degradation Kinetics)

By a News Reporter-Staff News Editor at Science Letter -- Investigators discuss new findings in Science. According to news reporting originating in West Lafayette, Indiana, by NewsRx journalists, research stated, "Highly structured network polymers are prepared via a molecular layer by layer technique (mLbL) and used as a model system to study aqueous degradation of polymer thin films in real time. Quantitative analysis of the degradation kinetics was enabled by the use of a quartz crystal microbalance (QCM)."

The news reporters obtained a quote from the research from Purdue University, "We conclude that the common metric of halogen, specifically chlorine, exposure (concentration x time) to be an ineffective normalization unit and showed a multistage adsorption process consistent with the established chemical mechanism. Additionally, degradation progression was tracked at multiple points of exposure to determine the effects of chlorination on the chemical and morphological state of the polymer structure with X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM), respectively. The formation of known halogenation products were corroborated with XPS through the high resolution spectra. Insight into the heterogeneous nature of the nanostructural degradation was derived from the AFM images. Periodic rinsing was found to release adsorbed chlorine but had negligible benefits on extending the exposure limits of the polyamide film. Fluorinated amine monomer (3,4-difluoroaniline) was incorporated into the surface of the polymer to determine the effect of limiting N-halogenation and the formation of the halogenated ring product. The modified surface layer reduced the rate and magnitude of chlorine adsorption relative to the neat polyamide surface."

According to the news reporters, the research concluded: "The QCM technique was shown to be an effective tool for rapid and high fidelity evaluation of molecular degradation and modification strategies to increase device lifetimes."

For more information on this research see: QCM-Based Measurement of Chlorine-Induced Polymer Degradation Kinetics. Langmuir, 2014;30(29):8923-8930. Langmuir can be contacted at: Amer Chemical Soc, 1155 16TH St, NW, Washington, DC 20036, USA. (American Chemical Society - www.acs.org; Langmuir - www.pubs.acs.org/journal/langd5)

Our news correspondents report that additional information may be obtained by contacting L.T. Kearney, Purdue University, Div Environm & Ecol Engn, West Lafayette, IN 47907, United States (see also Science).

Keywords for this news article include: Indiana, Science, United States, West Lafayette, North and Central America

Our reports deliver fact-based news of research and discoveries from around the world. Copyright 2014, NewsRx LLC


For more stories covering the world of technology, please see HispanicBusiness' Tech Channel



Source: Science Letter


Story Tools






HispanicBusiness.com Facebook Linkedin Twitter RSS Feed Email Alerts & Newsletters