News Column

Reports from Johannes Kepler University Describe Recent Advances in Chromatography (Impact of biomolecule solute size on the transport and...

August 22, 2014



Reports from Johannes Kepler University Describe Recent Advances in Chromatography (Impact of biomolecule solute size on the transport and performance characteristics of analytical porous polymer monoliths)

By a News Reporter-Staff News Editor at Science Letter -- Investigators publish new report on Science. According to news originating from Leonding, Austria, by NewsRx editors, the research stated, "Porous monolithic poly(styrene-co-divinylbenzene) stationary phases in 4.6 mm ID analytical format have been investigated with respect to their transport properties probed by solutes of biological origin varying vastly in size. Elucidation of several properties of these benchmark and robust materials gave complementary insight."

Our news journalists obtained a quote from the research from Johannes Kepler University, "These are: (i) the porous polymers' apparent dry-state microscopic appearance, (ii) the columns porosity probed by the biomolecules and modulated by mobile phase solvent composition, (iii) the impact of probe solute size on apparent retention at varying mobile phase solvent compositions, and (iv) the elution performance under both nonretained and retained elution conditions. By varying the volume percentage of acetonitrile in the mobile phase, it is demonstrated that the monolithic scaffold shows a variable porosity experienced in particular by the larger sized solutes, while the smaller solutes are gradually less affected. The nanoscale swelling and salvation of porous monolithic adsorbents resulting in gel porosity varied with mobile phase solvent composition was, therefore, indicated. The plate height curves for the solutes under nonretained conditions show a moderate increase at increased flow velocity while approaching plateau values. These plateau values were in conjunction with a trend of a decreased performance at an increased molecular weight of the solute. The systematic shape of the plate height curves at increased flow velocity indicates pre-asymptotic dispersion, This is because the column bed aspect ratio of length-to-diameter is equal or smaller than 10. Imposing retention on the solutes at a constant flow velocity deteriorates isocratic elution performance, more pronouncedly for the larger sized solutes at even weak retention. This is explained with slow pore fluid-gel interface diffusion."

According to the news editors, the research concluded: "Additionally, the apparent retention factor for elution of the probe solutes becomes a function of flow rate, consequently a function of imposed pressure experienced by the scaffold."

For more information on this research see: Impact of biomolecule solute size on the transport and performance characteristics of analytical porous polymer monoliths. Journal of Chromatography A, 2014;1354():56-64. Journal of Chromatography A can be contacted at: Elsevier Science Bv, PO Box 211, 1000 Ae Amsterdam, Netherlands. (Elsevier - www.elsevier.com; Journal of Chromatography A - www.elsevier.com/wps/product/cws_home/502688)

The news correspondents report that additional information may be obtained from I. Nischang, Johannes Kepler Univ Linz, Inst Polymer Chem, A-4060 Leonding, Austria (see also Science).

Keywords for this news article include: Europe, Austria, Science, Leonding

Our reports deliver fact-based news of research and discoveries from around the world. Copyright 2014, NewsRx LLC


For more stories covering the world of technology, please see HispanicBusiness' Tech Channel



Source: Science Letter