Study Results from Polytechnic University in the Area of Patient Care Reported (Commissioning and quality assurance of an integrated system for...

July 25, 2014



Study Results from Polytechnic University in the Area of Patient Care Reported (Commissioning and quality assurance of an integrated system for patient positioning and setup verification in particle therapy)

By a News Reporter-Staff News Editor at Health & Medicine Week -- Research findings on Patient Care are discussed in a new report. According to news reporting out of Milano, Italy, by NewsRx editors, research stated, "In an increasing number of clinical indications, radiotherapy with accelerated particles shows relevant advantages when compared with high energy X-ray irradiation. However, due to the finite range of ions, particle therapy can be severely compromised by setup errors and geometric uncertainties."

Our news journalists obtained a quote from the research from Polytechnic University, "The purpose of this work is to describe the commissioning and the design of the quality assurance procedures for patient positioning and setup verification systems at the Italian National Center for Oncological Hadrontherapy (CNAO). The accuracy of systems installed in CNAO and devoted to patient positioning and setup verification have been assessed using a laser tracking device. The accuracy in calibration and image based setup verification relying on in room X-ray imaging system was also quantified. Quality assurance tests to check the integration among all patient setup systems were designed, and records of daily QA tests since the start of clinical operation (2011) are presented. The overall accuracy of the patient positioning system and the patient verification system motion was proved to be below 0.5 mm under all the examined conditions, with median values below the 0.3 mm threshold. Image based registration in phantom studies exhibited sub-millimetric accuracy in setup verification at both cranial and extra-cranial sites. The calibration residuals of the OTS were found consistent with the expectations, with peak values below 0.3 mm. Quality assurance tests, daily performed before clinical operation, confirm adequate integration and sub-millimetric setup accuracy. Robotic patient positioning was successfully integrated with optical tracking and stereoscopic X-ray verification for patient setup in particle therapy."

According to the news editors, the research concluded: "Sub-millimetric setup accuracy was achieved and consistently verified in daily clinical operation."

For more information on this research see: Commissioning and quality assurance of an integrated system for patient positioning and setup verification in particle therapy. Technology In Cancer Research and Treatment, 2014;13(4):303-14 (see also Patient Care).

Our news journalists report that additional information may be obtained by contacting A. Pella, Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milano, Italy. Additional authors for this research include M. Riboldi, B. Tagaste, D. Bianculli, M. Desplanques, G. Fontana, P. Cerveri, M. Seregni, G. Fattori, R. Orecchia and G. Baroni.

Keywords for this news article include: Italy, Milano, Europe, Therapy, Patient Care, Patient Positioning.

Our reports deliver fact-based news of research and discoveries from around the world. Copyright 2014, NewsRx LLC


For more stories covering the world of technology, please see HispanicBusiness' Tech Channel



Source: Health & Medicine Week


Story Tools






HispanicBusiness.com Facebook Linkedin Twitter RSS Feed Email Alerts & Newsletters